Search
Search Funnelback University
Did you mean economiespast |u:www-mech.eng.cam.ac.uk?
41 -
60 of
221
search results for Economics test |u:www-mech.eng.cam.ac.uk
where 4
match all words and 217
match some words.
Results that match 1 of 2 words
-
doi:10.1016/j.ijsolstr.2005.05.017
www-mech.eng.cam.ac.uk/profiles/fleck/papers/204.pdf30 Mar 2006: 3. Results. 3.1. Tensile tests. The tensile test results are summarised in Table 2. ... 3.2. Compression tests. Three sets of compression tests were performed using the Celanese test rig, as summarised in Table 1.The uniaxial compressive stress versus -
Mode II fracture of an MMA adhesive layer: theory versus experiment
www-mech.eng.cam.ac.uk/profiles/fleck/papers/367.pdf22 Jul 2020: compressed between two smooth plates within the test machine to measure the uniaxial. ... whereas in parts (c) and (d) the tests are for a0 = 20 mm. -
*: Corresponding Author †: Currently at Civil and Urban ...
www-mech.eng.cam.ac.uk/profiles/fleck/papers/381.pdf11 Feb 2022: 19]. and Kim et al [20]. A combination of tensile and shear tests is necessary, with the test specimens. ... 3. Experimental Protocol. Detailed tests are required to characterize the material and calibrate model parameters. -
PII: S1359-6454(99)00097-X
www-mech.eng.cam.ac.uk/profiles/fleck/papers/108.pdf7 Jul 2004: fatigue tests: at the end of the fatigue test, when the. ... The specimen was then re-loaded and. the test was resumed. In the fatigue tests theunloading modulus was calculated from the changein axial strain upon reducing the applied stress. -
The microstructural basis for the mechanical properties and…
www-mech.eng.cam.ac.uk/profiles/fleck/papers/270.pdf25 Oct 2010: 3. Mechanical tests. Micro-indentation and nano-indentation tests, and uniaxialension and compression tests were performed on specimens. ... 4. Hardness tests. Fig. 8 shows the hardness H as a function of contact depth h foroth composites. -
PII: S0142-1123(01)00012-3
www-mech.eng.cam.ac.uk/profiles/fleck/papers/131.pdf7 Jul 2004: 3] for mono-tonic shear: fatigue tests were performed at 20 Hz on. ... 7.Repeat tests confirmed that the scatter in stress–strainresponse was negligible for face sheets of any giventhickness. -
PII: S0022-5096(01)00033-3
www-mech.eng.cam.ac.uk/profiles/fleck/papers/132.pdf16 May 2002: In unnotched tests, the specimens fail along the weakest plane, randomlylocated within the specimen. ... the current investigation due to limitations on the available size of materialsand test machines. -
PII: S0921-5093(99)00147-1
www-mech.eng.cam.ac.uk/profiles/fleck/papers/112.pdf7 Jul 2004: Such results for one test at smax = 0.85 MPa (Fig.6) reveal four key characteristics.1. ... of stage II cycles (at N]NT).The results for one such test with smax = 0.92 MPa arepresented on Fig. -
Normally closed microgrippers using a highly stressed…
www-mech.eng.cam.ac.uk/profiles/fleck/papers/196.pdf10 Aug 2009: Preliminary electrical tests have shown these microgrippers can beopened by 60–90 at an applied power of,20 mW. ... The prelimi-nary electrical test has shown that they can be opened by60–90 at a power of less than 20 mW. -
doi:10.1016/j.ijfatigue.2006.11.013
www-mech.eng.cam.ac.uk/profiles/fleck/papers/224.pdf31 Mar 2007: single-lapshear rig. Fig. 4. Sketch of the single-lap shear test rig used for monotonic andcyclic tests. ... failed by core shear fatigue in the cyclic tests and by faceyield in the monotonic test. -
Hydrogen embrittlement of a bimaterial C. Ayas, N.A. Fleck, ...
www-mech.eng.cam.ac.uk/profiles/fleck/papers/306.pdf28 Feb 2014: either pre-charged or are continuously charged with hydrogen dur-ing the test. ... 9) with T = 298K and VH =2.1 106 m3/mol: in all the tests, the test time exceeded the diffusion timeof lattice hydrogen in LAS which justifies the use of -
doi:10.1016/j.compositesb.2007.02.005
www-mech.eng.cam.ac.uk/profiles/fleck/papers/219.pdf2 Aug 2012: An oscilloscope measured and recorded the voltageversus time response during the compression tests. ... High strain rate compression test. Calibration of the SHPB system. Theory of measurements. -
doi:10.1016/j.compositesb.2007.02.005
www-mech.eng.cam.ac.uk/profiles/fleck/papers/167.pdf22 Jan 2008: An oscilloscope measured and recorded the voltageversus time response during the compression tests. ... High strain rate compression test. Calibration of the SHPB system. Theory of measurements. -
p308
www-mech.eng.cam.ac.uk/profiles/fleck/papers/308.pdf28 Jan 2014: barrier coating, and also describes a test method for the measurement of delamination. ... shut-down and restarts (and simulated in burner-rig tests) is idealised in Fig. -
doi:10.1016/j.compositesa.2004.03.006
www-mech.eng.cam.ac.uk/profiles/fleck/papers/178.pdf2 Aug 2012: delamination fracture tests, especially those featuring high-. resolution measurements of crack displacements and. ... to seat the specimen halves in the loading jig. 3.2. Shear tests. -
doi:10.1016/j.compositesa.2004.03.006
www-mech.eng.cam.ac.uk/profiles/fleck/papers/161.pdf21 Sep 2004: delamination fracture tests, especially those featuring high-. resolution measurements of crack displacements and. ... to seat the specimen halves in the loading jig. 3.2. Shear tests. -
INSTITUTE OF PHYSICS PUBLISHING JOURNAL OF MICROMECHANICS AND…
www-mech.eng.cam.ac.uk/profiles/fleck/papers/176.pdf6 Jul 2005: Table 5. Parameters of interest for preliminary design of on-chiptensile test machine. ... carried out on-chip bending tests to measure Young’s modulusof thin films. -
doi:10.1016/S1359-6454(03)00432-4
www-mech.eng.cam.ac.uk/profiles/fleck/papers/168.pdf26 Nov 2003: All tests were carried out at temperatures inthe range of 17–21 C. ... Experimental procedure. Choice of materials. Preliminary measurements. Polarization rotation test. Proportional loading test. -
doi:10.1016/j.euromechsol.2004.01.007
www-mech.eng.cam.ac.uk/profiles/fleck/papers/173.pdf8 Nov 2004: 8 5 1. 4. Measurement protocol. Compression tests were performed in the out-of-plane, 3-direction, of the woven core sandwich plates, as sketchedA screw-driven test machine was used ... core. The applied load was measured using thecell of the test machine -
doi:10.1016/j.ijmecsci.2004.11.010
www-mech.eng.cam.ac.uk/profiles/fleck/papers/201.pdf20 Jun 2005: 3.3.1. Compression tests. Compression experiments were conducted in a screw driven test machine with load measuredvia the load cell of the test machine and compressive strain deduced by measuring ... Next, conicalindentation tests in the axial direction,
Search history
Recently clicked results
Recently clicked results
Your click history is empty.
Recent searches
Recent searches
Your search history is empty.