Design & Manufacture of Stiffened Spring-Back Reflector…
www-civ.eng.cam.ac.uk/dsl/publications/AIAA-2005-2048.pdf17 May 2005: chosen to have a stiff-ener width of 0.06R = 24 mm, load angle γ = 7, hingeangle η = 14 and a stiffener thickness of 2 materialplies. ... This results in a plan stiffener width of22.6 mm, compared to that of 24 mm in Config VI.It also worth noting that -
AIAA 2004-1529Multi-Configuration Space FramesT. Schioler and S.…
www-civ.eng.cam.ac.uk/dsl/Schioler/publications/SDM2004.pdf30 Jan 2005: W = PE δwsin2θcosθ. (23). But, since. φ =π. 2 2θ (24). -
Thin-Shell Deployable Reflectors with Collapsible Stiffeners: Part I…
www-civ.eng.cam.ac.uk/dsl/publications/Reflectors-with-stiffeners.pdf1 Mar 2005: C90 2.72 24.76 4.18 39.18 0.274. Table 3. Comparison of optimized Configuration D. ... 24 of 28. Tan & Pellegrino. of given width and thickness, shortening the slits at the end of diameter d1 increases the.