Search

Search Funnelback University

Search powered by Funnelback
1 - 19 of 19 search results for Economics test |u:www-mech.eng.cam.ac.uk where 0 match all words and 19 match some words.
  1. Results that match 1 of 2 words

  2. doi:10.1016/j.scriptamat.2006.12.035

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/272.pdf
    10 Aug 2009: the 25 mm thick platesof the shear test apparatus and straddling the core. ... The tests were conductedin the servo-hydraulic test machine in load control at20 Hz.
  3. The fracture toughness of a cordierite square lattice

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/267.pdf
    19 Nov 2009: A test method is thereby developed for the mode Ifracture toughness of the lattice. ... Smaller specimens thereby suffice forthe SENB geometry as a fracture toughness test method.
  4. doi:10.1016/j.jeurceramsoc.2009.01.008

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/256.pdf
    29 May 2009: ound that the Metripol system was unable to identify |sin δ|,and I0/2 directly throughout the tests. ... The values ofsin δ| cycle several times during this test, indicating that multiplerders of birefringence are reached (δ π).
  5. Normally closed microgrippers using a highly stressed…

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/196.pdf
    10 Aug 2009: Preliminary electrical tests have shown these microgrippers can beopened by 60–90 at an applied power of,20 mW. ... The prelimi-nary electrical test has shown that they can be opened by60–90 at a power of less than 20 mW.
  6. doi:10.1016/j.ijsolstr.2006.07.015

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/220.pdf
    10 Aug 2009: 3.1. Uniaxial tests on face-sheet materials. The tests on the composite face-sheets were conducted in a screw-driven test machine at a nominal appliedstrain rate of 103 s1. ... The axial strainin both the compression and tension tests was measured by
  7. 1 spsFsea c�clhchhh atscnhp r Jsb J Downlo F. ...

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/244.pdf
    27 Jul 2009: These experiments are now reported. 3 Experimental InvestigationA series of compressive tests was performed on square honey-. ... 3c. A series of compression tests was performed on the macro-scopic sandwich panels.
  8. doi:10.1016/j.ijmecsci.2007.07.007

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/233.pdf
    10 Aug 2009: Consequently, the face-sheets of the Y-frame sandwich could slide past eachother during the uniaxial compression test. ... A pair of specimens was usedin each double-lap shear test, again using the apparatussketched in Fig.
  9. doi:10.1016/j.ijsolstr.2008.03.017

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/243.pdf
    10 Aug 2009: 2a and b, respectively. These compression tests were conducted on 6 mm 6 mm 6 mm cuboidal specimens in ascrew-driven test machine with the specimens compressed between lubricated flat platens. ... A select number of repeat tests were conducted for each
  10. doi:10.1016/j.ijsolstr.2007.02.015

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/271.pdf
    10 Aug 2009: measurements of the applied load from the load cell of the test machine. ... 2.4. Dynamic test protocol. The dynamic out-of-plane compressive responses of the corrugated and Y-frame cores were measured viadirect impact tests in which the forces were
  11. The dynamic response of clamped rectangular Y-frame and corrugated…

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/246.pdf
    8 Aug 2009: to monolithic beams of equalareal mass; in these tests, the prismatic axis of the cores wasaligned with the longitudinal axis of the beams. ... Protocol for the dynamic tests. Experimental results. Effect of projectile momentum upon the deformation of
  12. QuintanaFleck-Text-version3

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/266.pdf
    25 Mar 2009: 10. of the three-point bend test, including span S , height H and crack depth ratio a B. ... This conclu-sion is inconsistent with the definition of fracture toughness – a material property independent of test geometry.
  13. Journal of The Electrochemical Society, 153 �10� D155-D161 �2006� ...

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/183.pdf
    10 Aug 2009: a metal film and its micro-structure, especially when the beam-bending test is used. ... The high resistivity is obtained from microfabricated test struc-tures with a thickness of 0.4–0.7 m.
  14. Size effects in the bending of thin foils

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/258.pdf
    27 Jul 2009: In this test, a metallic foil of thickness in the range 10–150 lm is bent over a circular cylindrical bar whosediameter sets the value of applied curvature. ... The bending test is a complementary test method to the wire torsion test of [10].
  15. The influence of mechanical constraint upon the switching of a…

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/257.pdf
    27 Jul 2009: Geometry C (Fig. 2(c)): an unpassivated ferroelectric island withelastic electrode layers, on a Si substrate; this geometry istypical of a laboratory test structure. ... This ge-ometry represents an idealised laboratory test structure withelectrode
  16. C:/Documents and Settings/Martin Idiart/My Documents/Papers/Size…

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/262.pdf
    7 Feb 2009: In contrast, no size. effects were observed in the tension tests.
  17. QuintanaFleck_JSSM_RevisedText2

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/251.pdf
    8 Aug 2009: Hence, it would collapse by local buckling in an unnotched strength test, but it would fail by the attainment of the tensile strength of the cell wall material in a fracture ... toughness test.
  18. 1 ppGstfcwflcechtmmMoi tbtmtstqs oQ JrR J Downlo I. Quintana ...

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/240.pdf
    27 Jul 2009: 1. This. s a common test geometry and is representative of practical ap-lications.
  19. A mathematical basis for strain-gradient plasticity theory. Part II…

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/254.pdf
    10 Jul 2009: This is analogous to the case of a conventional,rigid-plastic solid where the Cauchy stress is not defined within a rigid region, and cannot be used in order to test
  20. Compressive response of a sandwich plate containing a cracked…

    www-mech.eng.cam.ac.uk/profiles/fleck/papers/265.pdf
    20 Jun 2009: 3 for the unnotchedcompressive strength. For any given material the local failure mechanism in a compressive fracture toughness test can bedifferent from that in an unnotched compressive strength test.

Refine your results

Search history

Recently clicked results

Recently clicked results

Your click history is empty.

Recent searches

Recent searches

Your search history is empty.